1 - 20 de 47
1.
G Ital Cardiol (Rome) ; 25(5): 327-339, 2024 05.
Article It | MEDLINE | ID: mdl-38639123

For many years, cardiac pacing has been based on the stimulation of right ventricular common myocardium to correct diseases of the conduction system. The birth and the development of cardiac resynchronization have led to growing interest in the correction and prevention of pacing-induced dyssynchrony. Many observational studies and some randomized clinical trials have shown that conduction system pacing (CSP) can not only prevent pacing-induced dyssynchrony but can also correct proximal conduction system blocks, with reduction of QRS duration and with equal or greater effectiveness than biventricular pacing. Based on these results, many Italian electrophysiologists have changed the stimulation target from the right ventricular common myocardium to CSP. The two techniques with greater clinical impact are the His bundle stimulation and the left bundle branch pacing. The latter, in particular, because of its easier implantation technique and better electric parameters, is spreading like wildfire and is representing a real revolution in the cardiac pacing field. However, despite the growing amount of data, until now, the European Society of Cardiology guidelines give a very limited role to CSP.


Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block , Treatment Outcome , Electrocardiography/methods , Heart Conduction System , Cardiac Resynchronization Therapy/methods , Myocardium , Heart Failure/therapy
2.
Circulation ; 149(5): 379-390, 2024 01 30.
Article En | MEDLINE | ID: mdl-37950738

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Cardiac Resynchronization Therapy , Heart Failure , Tachycardia, Ventricular , Humans , Cardiac Resynchronization Therapy/adverse effects , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy , Heart Failure/epidemiology , Heart Failure/therapy , Electrocardiography
3.
J Interv Card Electrophysiol ; 67(1): 175-182, 2024 Jan.
Article En | MEDLINE | ID: mdl-37365481

BACKGROUND: The Medtronic SelectSecure Model 3830 lumenless lead (Medtronic, Inc., Minneapolis, MN) is commonly used for conduction system pacing (CSP). However, with this increased use, the potential need for transvenous lead extraction (TLE) also will increase. While extraction of endocardial 3830 leads is rather well described especially in pediatric and adult congenital heart disease population, there is very limited data on extraction of CSP leads. In the present study, we reported our preliminary experience on TLE of CSP leads and provided technical considerations. METHODS: The study population comprised 6 consecutive patients (67% male; mean age 70 ± 22 years) with CSP leads (3830 leads), including left bundle branch pacing (LBBP) lead (n = 3) and His pacing lead (n = 3) undergoing TLE. Overall target leads were 17. The mean implant duration time of CSP leads was 97 ± 90 months [range 8-193). RESULTS: Manual traction was successful in 2 cases and mechanical extraction tools were required in the remaining cases. Sixteen leads (94%) were completely extracted, whereas incomplete removal was observed in one lead (6%) among 1 patient. Of note, in the only lead incompletely removed, we observed retention of < 1-cm remnant of lead material consisting of the screw of 3830 LBBP lead into the interventricular septum. No failure of lead extraction was reported and no major complications occurred. CONCLUSIONS: Our findings demonstrated that at an experienced center the success of TLE of chronically implanted CSP leads is high in the absence of major complications also when mechanical extraction tools are needed.


Heart Defects, Congenital , Pacemaker, Artificial , Humans , Male , Adult , Child , Middle Aged , Aged , Aged, 80 and over , Female , Retrospective Studies , Device Removal , Heart Defects, Congenital/surgery , Cardiac Pacing, Artificial , Cardiac Conduction System Disease
4.
Indian Pacing Electrophysiol J ; 23(6): 177-182, 2023.
Article En | MEDLINE | ID: mdl-37598755

INTRODUCTION: Restoring physiological cardiac electrical activity in patients with conduction disease can be crucial for the survival and quality of life. Conduction system pacing (CSP) is a valuable option, although it is limited by technical challenges in difficult anatomies. 3D electroanatomical mapping (3D-EAM) can support CSP ensuring high electro-anatomical precision and low fluoroscopy. OBJECTIVES: We evaluated the feasibility and effectiveness of a systematic 3D-EAM use to guide CSP in difficult anatomical scenarios (highly dilated atria, congenital cardiomyopathies, failed biventricular implants (BiV) and pacing-induced cardiomyopathy (PICM)). METHODS: Forty-three consecutive patients (27 males, 75 ± 10 years old) with standard pacing indications and difficult anatomical scenarios were included. The right atrium, His cloud, and atrio-ventricular septum were reconstructed by 3D-EAM. The His bundle (HB) was the initial target, while left bundle branch area pacing (LBBAP) was aimed at in case of unsatisfactory parameters, sub-optimally paced QRS, or impossibility of reaching the HB. RESULTS: CSP was successful in 37 (86%) patients (15 HBP; 22 LBBAP). Mean mapping, fluoroscopy, and procedural times were 18 ± 7 min, 7 ± 5 min, 98 ± 47 min, respectively. The mean pacing threshold, R wave sensing, and pacing impedance of CSP lead were 1.2 ± 0.5V@0.5ms, 11.4 ± 6.2 mV, 736 ± 306 Ω, respectively. Baseline and paced QRS were 139 ± 38 ms and 114 ± 23 ms, respectively. No procedural complications were observed. CONCLUSIONS: 3D-EAM allowed the accurate definition of the His cloud and high ventricular septum and effectively guided CSP. It facilitated CSP in complex anatomies, with a procedural success rate of 86%. The results were satisfactory and reproducible, with acceptable fluoroscopy and procedural times.

5.
Front Cardiovasc Med ; 10: 1236369, 2023.
Article En | MEDLINE | ID: mdl-37636299

Patients with symptomatic heart failure (HF) and left bundle branch block (LBBB) are currently treated with biventricular pacing (BiV) which has a Class IA recommendation. Given the possibility to re-establish the inter and intra-ventricular synchrony, BiV is commonly referred to as cardiac resynchronization therapy (CRT). This wording is widely utilized and over time the terms BiV and CRT have become interchangeable. Conduction system pacing (CSP) is emerging as a valid therapeutic opportunity to obtain CRT restoring the native conduction via the Purkinje network. Therefore the acronym CRT is no longer synonymous with BiV only but could also refer to CSP. A terminology update is needed to include the resource of CSP to ensure better communication among all the stakeholders involved in managing recipients of cardiac devices and should be a fundamental step in advancing the quality of patient care. Making use of the NBG code to describe the implantable cardiac device would ease such terminology update, since only the first three positions of the five letters NBG code are commonly utilized, while the last two are rarely used.

6.
Eur Heart J Suppl ; 25(Suppl C): C234-C241, 2023 May.
Article En | MEDLINE | ID: mdl-37125312

The conduction system of the human heart is composed of specialized cardiomyocytes that initiate and propagate the electric impulse with consequent rhythmic and synchronized contraction of the atria and ventricles, resulting in the normal cardiac cycle. Although the His-Purkinje system (HPS) was already described more than a century ago, there has been a recent resurgence of conduction system pacing (CSP), where pacing leads are positioned in the His bundle region and left bundle branch area to provide physiological cardiac activation as alternatives to the unnatural myocardial stimulation obtained with conventional right ventricular and biventricular pacing. In this review, we describe the fundamental anatomical and pathophysiological aspects of the specialized HPS along with the CSP technique's nuts and bolts to highlight its potential benefits in everyday clinical practice.

7.
J Am Coll Cardiol ; 82(3): 228-241, 2023 07 18.
Article En | MEDLINE | ID: mdl-37220862

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well established therapy in patients with reduced left ventricular ejection fraction (LVEF), heart failure, and wide QRS or expected frequent ventricular pacing. Left bundle branch area pacing (LBBAP) has recently been shown to be a safe alternative to BVP. OBJECTIVES: The aim of this study was to compare the clinical outcomes between BVP and LBBAP among patients undergoing CRT. METHODS: This observational study included patients with LVEF ≤35% who underwent BVP or LBBAP for the first time for Class I or II indications for CRT from January 2018 to June 2022 at 15 international centers. The primary outcome was the composite endpoint of time to death or heart failure hospitalization (HFH). Secondary outcomes included endpoints of death, HFH, and echocardiographic changes. RESULTS: A total of 1,778 patients met inclusion criteria: 981 BVP, 797 LBBAP. The mean age was 69 ± 12 years, 32% were female, 48% had coronary artery disease, and mean LVEF was 27% ± 6%. Paced QRS duration in LBBAP was significantly narrower than baseline (128 ± 19 ms vs 161 ± 28 ms; P < 0.001) and significantly narrower compared to BVP (144 ± 23 ms; P < 0.001). Following CRT, LVEF improved from 27% ± 6% to 41% ± 13% (P < 0.001) with LBBAP compared with an increase from 27% ± 7% to 37% ± 12% (P < 0.001) with BVP, with significantly greater change from baseline with LBBAP (13% ± 12% vs 10% ± 12%; P < 0.001). On multivariable regression analysis, the primary outcome was significantly reduced with LBBAP compared with BVP (20.8% vs 28%; HR: 1.495; 95% CI: 1.213-1.842; P < 0.001). CONCLUSIONS: LBBAP improved clinical outcomes compared with BVP in patients with CRT indications and may be a reasonable alternative to BVP.


Cardiac Resynchronization Therapy , Heart Failure , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Stroke Volume , Electrocardiography , Ventricular Function, Left , Treatment Outcome , Heart Failure/therapy
9.
Europace ; 25(5)2023 05 19.
Article En | MEDLINE | ID: mdl-36974970

AIMS: In patients with prolonged atrioventricular (AV) conduction and pacemaker (PM) indication due to sinus node disease (SND) or intermittent AV-block who do not need continuous ventricular pacing (VP), it may be difficult to determine which strategy to adopt. Currently, the standard of care is to minimize unnecessary VP by specific VP avoidance (VPA) algorithms. The superiority of this strategy over standard DDD or DDD rate-responsive (DDD/DDDR) in improving clinical outcomes is controversial, probably owing to the prolongation of the atrialventricular conduction (PR interval) caused by the algorithms. Conduction system pacing (CSP) may offer the most physiological-VP approach, providing appropriate AV conduction and preventing pacing-induced dyssynchrony. METHODS AND RESULTS: PhysioVP-AF is a prospective, controlled, randomized, single-blind trial designed to determine whether atrial-synchronized conduction system pacing (DDD-CSP) is superior to standard DDD-VPA pacing in terms of 3-year reduction of persistent-AF occurrence. Cardiovascular hospitalization, quality-of-life, and safety will be evaluated. Patients with indication for permanent DDD pacing for SND or intermittent AV-block and prolonged AV conduction (PR interval > 180 ms) will be randomized (1:1 ratio) to DDD-VPA (VPA-algorithms ON, septal/apex position) or to DDD-CSP (His bundle or left bundle branch area pacing, AV-delay setting to control PR interval, VPA-algorithms OFF). Approximately 400 patients will be randomized in 24 months in 13 Italian centres. CONCLUSION: The PhysioVP-AF study will provide an essential contribution to patient management with prolonged AV conduction and PM indication for sinus nodal disease or paroxysmal 2nd-degree AV-block by determining whether CSP combined with a controlled PR interval is superior to standard management that minimizes unnecessary VP in terms of reducing clinical outcomes.


Atrial Fibrillation , Atrioventricular Block , Pacemaker, Artificial , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Prospective Studies , Single-Blind Method , Sick Sinus Syndrome/complications , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/therapy
11.
G Ital Cardiol (Rome) ; 23(10): 775-792, 2022 Oct.
Article It | MEDLINE | ID: mdl-36169129

Cardiovascular diseases are still the main cause of death among women despite the improvements in treatment and prognosis achieved in the last 30 years of research. The determinant factors and causes have not been completely identified but the role of "gender" is now recognized. It is well known that women tend to develop cardiovascular disease at an older age than men, and have a high probability of manifesting atypical symptoms not often recognized. Other factors may also co-exist in women, which may favor the onset of specific cardiac diseases such as those with a sex-specific etiology (differential effects of estrogens, pregnancy pathologies, etc.) and those with a different gender expression of specific and prevalent risk factors, inflammatory and autoimmune diseases and cancer. Whether the gender differences observed in cardiovascular outcomes are influenced by real biological differences remains a matter of debate.This ANMCO position paper aims at providing the state of the research on this topic, with particular attention to the diagnostic aspects and to care organization.


Cardiovascular Diseases , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/etiology , Estrogens , Female , Humans , Male , Prognosis , Risk Factors , Sex Factors
12.
Card Electrophysiol Clin ; 14(2): 141-149, 2022 06.
Article En | MEDLINE | ID: mdl-35715073

His Bundle Pacing (HBP) is a form of physiologic pacing achieved through implantation of a pacing electrode into the His bundle. HBP began 20 years ago without any dedicated tools. As specific tools became available HBP quickly spread and proved to be a viable alternative to traditional right ventricle pacing. HBP is reliable and effective in preserving the physiologic ventricular synchrony with clinical benefits particularly evident when a high percentage of pacing is required. Unipolar signals from the lead tip guide the implant. 3D electroanatomical mapping could further assist the procedure.


Bundle of His , Cardiac Pacing, Artificial , Cardiac Pacing, Artificial/methods , Electrocardiography , Heart Ventricles/surgery , Humans , Treatment Outcome
13.
J Cardiovasc Med (Hagerstown) ; 23(6): 353-358, 2022 06 01.
Article En | MEDLINE | ID: mdl-34580253

Interventional cardiologists are significantly exposed to X- rays and no dose of radiation may be considered well tolerated or harmless. Leaded aprons protect the trunk and the thyroid gland, leaded glasses protect the eyes. The operator's legs, arms, neck and head are, instead, not fully protected. In fact, the operator's brain remains the closest part to the primary X-ray beam and scatter in most interventional procedures and specifically the physician's front head is the most exposed region during device implantation performed at the patient's side. After the initial description of cases of brain and neck tumours, additional reports on head and neck malignancies have been published. Although a direct link between operator radiation exposure and brain cancer has not been established, these reports have heightened awareness of a potential association. The use of lead-based cranial dedicated shields may help reduce operator exposure but upward scattered radiation, weight and poor tolerability have raised concerns and hindered widespread acceptance. The purpose of this review is to describe current knowledge on occupational X-ray exposure of interventional cardiologists, with a special focus on the potential risks for the head and neck and efficacy of available protection devices.


Cardiology , Radiation Exposure , Radiation Protection , Humans , Radiation Dosage , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Radiation Protection/methods , Radiography, Interventional/adverse effects , X-Rays
14.
J Cardiovasc Med (Hagerstown) ; 23(1): 22-27, 2022 01 01.
Article En | MEDLINE | ID: mdl-34545009

AIMS: The coronavirus disease-19 (COVID-19) outbreak has been recently associated with lower hospitalization rates for acute coronary syndromes. Aim of the study was to investigate whether a similar behaviour is observed in admissions for urgent pacemaker implant. METHODS: This retrospective study included 1315 patients from 18 hospitals in Northern Italy with a high number of COVID-19 cases. Hospitalization rates for urgent pacemaker implant were compared between the following periods: 20 February to 20 April 2020 (case period); from 1 January to 19 February 2020 (intra-year control period); from 20 February to 20 April 2019 (inter-year control period). RESULTS: The incidence rate of urgent implants was 5.0/day in the case period, 6.0/day in the intra-year control period and 5.8/day in the inter-year control period. Incidence rate in the case period was significantly lower than both the intra-year [incidence rate ratio (IRR): 0.81, 95% CI 0.67-0.99, P = 0.040] and inter-year control periods (IRR: 0.79, 95% CI 0.66-0.95, P = 0.012); this reduction was highest after the national lockdown (IRR 0.68, 95% CI 0.52-0.91, P = 0.009). The prevalence of residents in rural areas undergoing urgent pacemaker implant was lower in the case period (36%) than in both the intra-year (47%, P = 0.03) and inter-year control periods (51%, P = 0.002). Elective pacemaker implants also decreased in the case period, with the incidence rate here being 3.5/day vs. 6.4/day in the intra-year (-45%) and 6.9/day in the inter-year period (-49%). CONCLUSION: Despite severe clinical patterns, the COVID-19 outbreak has negatively affected the population presentation to Emergency Departments for bradyarrhythmias requiring urgent pacemaker implant in Northern Italy. This mainly occurred after the national lockdown and concerned patients living in rural areas.


Bradycardia/epidemiology , Bradycardia/therapy , COVID-19/epidemiology , Disease Outbreaks/statistics & numerical data , Elective Surgical Procedures/statistics & numerical data , Emergencies/epidemiology , Pacemaker, Artificial/statistics & numerical data , Aged , Aged, 80 and over , Female , Hospitalization/statistics & numerical data , Humans , Incidence , Italy/epidemiology , Male , Retrospective Studies
15.
J Clin Med ; 10(24)2021 Dec 17.
Article En | MEDLINE | ID: mdl-34945236

Background: Reduction in QRS area after cardiac resynchronization therapy (CRT) is associated with improved long-term clinical outcome. The aim of this study was to investigate whether the reduction in QRS area is associated with hemodynamic improvement by pacing different LV sites and can be used to guide LV lead placement. Methods: Patients with a class Ia/IIa CRT indication were prospectively included from three hospitals. Acute hemodynamic response was assessed as the relative change in maximum rate of rise of left ventricular (LV) pressure (%∆LVdP/dtmax). Change in QRS area (∆QRS area), in QRS duration (∆QRS duration), and %∆LVdP/dtmax were studied in relation to different LV pacing locations within a patient. Results: Data from 52 patients paced at 188 different LV pacing sites were investigated. Lateral LV pacing resulted in a larger %∆LVdP/dtmax than anterior or posterior pacing (p = 0.0007). A similar trend was found for ∆QRS area (p = 0.001) but not for ∆QRS duration (p = 0.23). Pacing from the proximal electrode pair resulted in a larger %∆LVdP/dtmax (p = 0.004), and ∆QRS area (p = 0.003) but not ∆QRS duration (p = 0.77). Within patients, correlation between ∆QRS area and %∆LVdP/dtmax was 0.76 (median, IQR 0.35; 0,89). Conclusion: Within patients, ∆QRS area is associated with %∆LVdP/dtmax at different LV pacing locations. Therefore, QRS area, which is an easily, noninvasively obtainable and objective parameter, may be useful to guide LV lead placement in CRT.

16.
J Am Heart Assoc ; 10(22): e021861, 2021 11 16.
Article En | MEDLINE | ID: mdl-34779249

Background Sudden cardiac arrest (SCA) may be caused by an acute and reversible myocardial injury, a chronic and irreversible myocardial damage, or a primary ventricular arrhythmia. Cardiac magnetic resonance imaging may identify myocardial edema (ME), which denotes acute and reversible myocardial damage. We evaluated the arrhythmic outcome of SCA survivors during follow-up and tested the prognostic role of ME. Methods and Results We included a consecutive series of 101 (71% men, median age 47 years) SCA survivors from 9 collaborative centers who underwent early (<1 month) cardiac magnetic resonance imaging and received an implantable cardioverter-defibrillator (ICD). On T2-weighted sequences, ME was found in 18 of 101 (18%) patients. According to cardiac magnetic resonance imaging findings, the arrhythmic SCA was ascribed to acute myocardial injury (either ischemic [n=10] or inflammatory [n=8]), to chronic structural heart diseases (ischemic heart disease [n=11], cardiomyopathy [n=20], or other [n=23]), or to primarily arrhythmic syndrome (n=29). During a follow-up of 47 months (28 to 67 months), 24 of 101 (24%) patients received an appropriate ICD intervention. ME was associated with a significantly higher survival free from both any ICD interventions (log-rank=0.04) and ICD shocks (log-rank=0.03) and remained an independent predictor of better arrhythmic outcome after adjustment for left ventricular ejection fraction and late gadolinium enhancement. The risk of appropriate ICD intervention was unrelated to the type of underlying heart disease. Conclusions ME on early cardiac magnetic resonance imaging, which denotes an acute and transient arrhythmogenic substrate, predicted a favorable long-term arrhythmic outcome of SCA survivors. These findings may have a substantial impact on future guidelines on the management of SCA survivors.


Defibrillators, Implantable , Out-of-Hospital Cardiac Arrest , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/therapy , Contrast Media , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Edema , Female , Gadolinium , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Male , Middle Aged , Prognosis , Risk Factors , Stroke Volume , Survivors , Ventricular Function, Left
17.
J Cardiovasc Electrophysiol ; 32(1): 110-116, 2021 01.
Article En | MEDLINE | ID: mdl-33179400

INTRODUCTION: In patients with sinus node disease (SND), the dual-chamber pacemaker (PM) is programmed in DDDR mode with an algorithm to avoid unnecessary right ventricular (RV) pacing. This pacing mode may prolong PR interval with consequently atrioventricular (AV) asynchrony which is associated with a higher risk of atrial fibrillation (AF). We evaluate whether preserving AV synchrony by setting a fixed AV delay during physiological RV pacing, that is, His bundle pacing (HBP), could reduce the risk of AF occurrence in comparison with a standard pacing mode with an algorithm to avoid unnecessary RV pacing (DDD-VPA). METHODS AND RESULTS: We collected retrospective data from 313 consecutive patients who had undergone PM for SND. The first occurrence of persistent AF (>7 consecutive days) as a function of the pacing mode was evaluated. HBP and DDD-VPA were implemented in 82 and 231 patients, respectively. Persistent AF occurred in 128 (40.9%) patients over a median follow-up of 70 months (67-105). The DDD-VPA pacing mode was significantly correlated with the occurrence of persistent AF only when the basal PR was long (>180 ms). The risk of persistent AF was significantly lower in patients on HBP than in those on DDD-VPA, adjusted HR = .57 (95% CI, .36- .89, p=.014). Other independent predictors of persistent AF occurrence were: A history of AF (HR = 3.91; 95% CI, 2.48-6.19, p = .001), age, and long PR interval (HR = 2.98; 95% CI, 2.00-4.43, p=.001). CONCLUSION: In SND patients and long basal PR interval, the HBP may reduce the risk of persistent AF in comparison with the DDD-VPA.


Atrial Fibrillation , Pacemaker, Artificial , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Bundle of His , Cardiac Pacing, Artificial , Humans , Retrospective Studies , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/therapy
...